17 Membrane Pressure & Temperature Correction Tables
Technical & Engineering
To adjust from 60 psi (414kPa) to another pressure multiply
the production rate by the correction factor.
To adjust from 77° F (25° C) to another temperature, multiply
the production rate by the correction factor.
To adjust from pressure to standard conditions divide by
the factor.
To adjust from a temperature to standard conditions divide
by the factor.
Pressure Correction Factors for Thin Film Composite
(T.F.C.) Membrane Production Rate
Pressure
^pse
^kPa
Correction
Factor
10
69
.17
84
15
103
.25
88
20
138
.33
90
25
172
.42
92
30
207
.50
93
35
241
.58
93
40
276
.67
94
45
310
.75
94
50
345
.83
94
55
379
.92
94
60
414
1.00
94
65
448
1.08
94
70
483
1.17
95
75
517
1.25
95
80
552
1.33
95
85
586
1.42
95
90
621
1.50
96
95
655
1.58
96
100
689
1.67
96
*Percent rejection of Total Dissolved Solids
17 - 16
Percent
Rejection*
Temperature Correction Factors for Thin Film Composite
(T.F.C.) Membrane Production Rate
Temperature
F
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
100
C
10.0
10.6
11.1
11.6
12.2
12.8
13.4
13.9
14.4
15.0
15.5
16.1
16.7
17.2
17.8
18.4
18.9
19.5
20.0
20.6
21.1
21.7
22.2
22.8
23.4
23.9
24.5
25.0
25.6
26.1
26.7
27.2
27.8
28.4
28.9
29.5
689
For more information visit – NelsenCorp.com • NelsenWaterSolutions.com • VESTAwater.com
All prices and products subject to change without notice. ©Nelsen Corporation
Correction
Factor
1.711
1.676
1.642
1.611
1.576
1.541
1.508
1.480
1.453
1.422
1.396
1.366
1.337
1.313
1.285
1.258
1.236
1.210
1.189
1.164
1.144
1.120
1.101
1.078
1.056
1.038
1.017
1.000
0.982
0.968
0.951
0.937
0.921
0.905
0.892
0.877
1.67